Page 9: Getting Started. If you love a cozy, comedic mystery, you'll love this 'whodunit' adventure. PXIe, 9-Slot (5 Hybrid Slots, 3 PXI Express Slots), Up to 1. NATIONAL INSTRUMENTS PXIE-1078. When using these terminal blocks for verification connect only oneRe: PXIe card not shown inside chassi for NI Max. Meets MIL-PRF-28800F requirements. 5 NI PXI Platform Services 14. Fax: (240) 376-1381. PXI Express chassis have a power supply that can be controlled by the PXI Express system controller. PXIe-1078 This document includes specifications for the PXIe-1078 chassis. Data Transfer Rates. 4 in. are not included with this equipment. Please note that the glyphs are also shown in the upper right hand corner of any PXI or PXIe card, adjacent to the fixing screw. To install a module, complete the following steps: Connect the AC power source to the PXI Express chassis before. Trigger route types are dynamic (the default), Away from Bus 1, Away from Bus 2, and Away from Bus 3. 04-10-2014 08:53 AM. PXI Series chassis pdf manual download. PXIe-4139 output and set the common-mode input of the PXIe-4302/4303 to zero volts. Can I send trigger from PXI_Trig 0-15 toThe PXIe‑8840 is an embedded controller for PXI systems. PDF. Join. Click "View Product Detail" i. An independent buffer (having a source impedance matched to the backplane and a skew of less than 500 ps between slots) drives PXI_CLK10 to each peripheral slot. Each PXI Trigger Line, PXI_Trig0 through PXI_Trig7, can be configured under the Routing column to be one of four different options. I always boot the PXI chassis up before my computer. 0f0. Refer to Chapter 1, Getting Started, for a description of the various slot types. 53 GHz Dual-Core Processor PXI Embedded Controller —The PXIe-8108 is a Intel Core 2 Duo embedded controller for PXI and CompactPCI systems. 03-26-2012 02:09 PM. To reduce the magnetic coupling between lines. Note The maximum power dissipated in the System Controller Slot should not exceed 140 W. NI-DAQmx Issue Details When I wake my computer from a sleep state and I attempt to access my NI-DAQmx hardware in NI MAX or my development environment I receive. 2 | ni. 0 ports, as well as a serial port, and other peripheral I/O. Previous versions are available only to customers with an active subscription license or service agreement for this product. 01-27-2022 09:00 PM. 75 GB/s PXI Chassis PXIe-1083 PXIe, 5-Slots, up to 2 GB/s PXI Chassis with integrated Thunderbolt 3 MXI-Express controller PXIe-8381 PXIe, x8, MXI-Express Interface, PXI Remote Control ModulePXIe-1078 PXIe-1082 PXIe-1082DC PXIe-1085 PXIe-1086. The Triggers tab in MAX allows users to route triggers across buses. If you can get this config utility to run it allows the PXIe MXI board to power up the chassis when you power up the host (if you have a compatible MXI kit). This section contains general installation instructions for installing a peripheral module in a NI PXIe-1078 chassis. PXIe-1078 PXIe-1082 PXIe-1082DC PXIe-1085 PXIe-1086. Underneath the main Chassis tab entry at the top, click on 2. The device is AC powered, and weighs 31 lb. Currently installing a new NI Chassis for test set-up, we have installed NI-PXIe 1078 chassis in test machine, which is not getting recognized in. PXIe-8360 MXI card (for communications) NI-SWITCH 18. 09-05-2018 02:45 AM - edited 09-05-2018 02:47 AM. I'm using a PXIe-1078 that communicates to my PC (Windows. Therefore, you can connect/configure it in the same way you would any other computer. † NI PXIe-1078 (199485x-01L) Refer to Figure 1 and the following steps for installation and removal instructions. For example, the a white circle inside a white. 예제, 문제해결 정보를 비롯한 다양한 기술지원 콘텐츠를 살펴보십시오. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Connection Accessory TB-4302 —. Product Family: 5999-01-681-3551, 5999016813551. NI-DAQmx Issue Details When I wake my computer from a sleep state and I attempt to. You can request repair, RMA, schedule calibration, or get technical support. PXIe-1078 PXIe-1073 PXIe-1085 Issue Details I have a PXI(e) chassis, such as the PXIe-1073, 1078 or 1085. Running ver 17 of "everythig", NIMAX, PXI platform services. Using a Phillips screwdriver, remove the screws. Order today, ships today. PXI-8110. 0. I have seen from user manual of PXIe-1078, System Reference Clock. When the power cord connected to the chassis, the green led on top is on - pressing the power button and nothing happens. Dynamic: The routes are left. The V1153 is designed for rugged high-bandwidth networking and interface applications. Where do I find it? Solution You can find them in the accessories if you were about to buy the chassis. ホーム サポート ドキュメント 寸法図 PXIe-1078ラックマウント 寸法図. Chassis configuration will be: slot1 : controller slot2-8 : PXIe-4330 slot9 : PXIe-4353 I have created one task in. Up to 82W per slot of power and cooling. Note PCI V (I/O) pins in Hybrid Peripheral Slots are connected to +5 V. Then go ahead and navigate to the directory C:Windows. What automatic power-up options are available for my PXI Express Chassis?. 1, PXI Platform Services will now include firmware files for the PXIe-1095 and PXIe-1084 chassis. Additionally, based on. I started working with a NI PXIe 1078 chassis with a NI PXIe 8133 controller and a few others modules quite recently. 2, 4, 5, 8, 9 and 18 Slot Versions Available. Note Specifications are subject to change without notice. in NIMax, the backplane firmware shows up as version 1. The Big River™ DM-125-3U PXI Express Storage Unit provides disk storage resources to PCI Express based systems. The following section provides information about the PXIe-1088 AC input and DC output. In Auto mode the chassis fan control system uses intake air temperature as the input for controlling the speed of the fans, which provides improved acoustic performance. Locate and expand the chassis needing the firmware update. The standard SCOUT receiver is available in 11 and 21 slot configurations to suit your preferred PXI chassis. The NI PXIe-8840 Quad-Core Controller incorporates an outside SMB association for use as a trigger information, output or watchdog timer. . Connection Accessory TB-4304 — SMU PXIe-4139 Noise (0. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。NI PXIe-1078 with NI PXIe-6541 and PXIe-8381 controller. 2 GB/s, Copper or Fiber-Optic Cable MXI-Express Device for PXI Remote Control—The PCIe‑8381 is an MXI‑Express remote controller for devices or systems cabled over PCI from a computer with a PCI Express slot. Open a service request. General Overrange 105% of. PXI slot 2: PXIe-2525 Multiplexer board. NI put a workaround for some Thunderbolt hosts in PXI Platform Services, but it's a hardware. The PXIe-1095 features a high-bandwidth backplane and up to 82 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. All current and previous versions are available on the PXIe Series Support Site. e. When streaming in both. Capacity. PXIe-1078 Rack Mount. The NI PXI Chassis have free ground shipping and a 1-3 year warranty, based on New, Remanufactured, or Repair Status of the model. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Switch 1 of SW1 controls the chassis inhibit mode. The PXIe‑1085 features a high-bandwidth, all-hybrid backplane to meet a wide range of high-performance test and measurement application needs. are not included with this equipment. The chassis contains two XNET cards for CAN communications. Other Names. Manuals. but I have only PXI-8231 controller with me , which can support for GIGE vision. ContentsRe: PXIe-8360 regognized but PXIe-1078 not recognized. Member. This symbol signifies which of the PXI (e) slots the card may be plugged into. A PXIe-4353 in slot 2 Two PXI-6238 and a 6722 in slots 5,6,and 7. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in up to five. The PXIe‑8840 is an embedded controller for PXI systems. Configure the PXIe-4139 to voltage output mode and enable remote sensing. Identify the two mounting screws for the PXIe-1095 that attach the power supply to the chassis. This optional upgrade provides inter-chassis trigger routing capability, higher accuracy CLK10, and CLK100, connectors for 10 MHz reference clock input and output, and remote chassis monitoring. PXIe-1078 This document includes specifications for the PXIe-1078 chassis. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Detailed View of PXIe-1095 Series Chassis . The PXIe MXI Express x1/x4/x8/x16 board can use this functionality to automatically power-on downstream PXIe chassis when the host PC is turned on, or even power-on the host PC when the chassis power is turned on. 包括ni pxi-1031,pxi-1036,pxie-1065,pxie-1071,pxie-1078,pxie-1085和pxie-1095在内的多种机箱型号从未将泡沫过滤器作为其设计的一部分。 您可以继续使用安装了过滤器的机箱。 ni建议例行(每6个月)按照指定的维护方式清洁过滤器或是完全移除泡沫过滤器。PXIe, 18-Slot (5 Hybrid Slots, 11 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis. . to verify your subscription or service agreement is valid. 1. Reported In shows products that are verified to work for the solution described in this article. NI-DAQmx. AC Input. The PCIe-6672 Timing and Sync card is able to send Trig signal on the PXI_TrigX and PXI_StarX lines. The controller will just put itself into a low power state as long as PXI Platform Services is installed and the NI PXI Resource Manager is set to Active. Its compact and lightweight form factor is ideal for minimizing the footprint of your installation, making it ideal for desktop or portable use cases. All the slots in the chassis are full so I cannot add another XNET card. Windows 10. (A slightly lower value may not cause. All analog input channels in all cards are configured for single point input. 0 ports, as well as a serial port, and other peripheral I/O. ; Download and save the file (the default option for some Internet browsers), and open it directly from. Hi, Recently I installed Scientific Linux 6. getDevices returns you the device and not the chassis and thus you see PXI 6358 and not PXIe1062Q. Now it does not want to boot (nothing show up on the display). What I'm trying to do is run LabVIEW on a separate laptop using the DAQ card connected to this chassis. com . Phone: (217) 352-9330. Fast Quotes & Shipping. Newark. 75 GB/s PXI Chassis —The PXIe‑1078 features a backplane that incorporates a PCI Express connection to every. Engineers use NI PXI to build high-performance, mixed-measurement systems for validation and production test. Inhibit Mode switch on your PXI/PXIe chassis will control the chassis inhibit mode. PXIe - PXIe: Most NI PXIe controllers (including remote, embedded, and rackmount), are compatible with any NI PXIe chassis. 2. エンジニアはNI PXIを使用して、検証と製造テストのための高性能な複合測定システムを構築. Solved! Go to Solution. Getting Started w/ PXIe-1078, Trouble with PXI-4070 drivers, configuring MAX, using SoftDMM. PXIe-1078 PXIe-1082 PXIe-1085 PXIe-1086 Driver. pxiおよびpxieシャーシの各スロットの下にシンボルマークが記載されています。. Re: where can i find the chassis file for import in MAX for drawing connection diagram before purchasing lhedlund. If using a MXI-Express connection, test a different PCI/PCIe slot. PXI slot 6: PXI-4065 DMM . Use the following recommendations for all signal connections to the NI PXIe-7862 : • Separate NI PXIe-7862 signal lines from high-current or high-voltage lines. A dialog box should open containing information about the firmware image selected. Check for visible damage to the metal work. The NI PXIe-1078 offers the flexibility to populate each peripheral slot with a PXI Express module or populate up to five slots with PXI With a shallow depth of 214. Each PXI Trigger Line, PXI_Trig0 through PXI_Trig7, can be configured under the Routing column to be one of four different options. 5500 for Availability. Refer to your peripheral module user manual for specific instructions and warnings. 2, 4, 5, 8, 9 and 18 Slot Versions Available; Hybrid slots for compatibility with PXI, PXI Express, CompactPCI, and CompactPCI Express; Up to 24 GB/s system and 8 GB/s per-slot dedicated bandwidth. This home was built in 1978 and. We have a PXIe-1078 connected to a computer through a PXIe-8360 and PXIe-8361. Active Participant. Part Number: 781622-01. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Standard SCOUT. Click View Accessories. It accepts up to a four-slot wide controller in one slot, with three slots available for either PXI Express or PXI modules. 2. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator;The command daq. Pricing and Availability on millions of electronic components from Digi-Key Electronics. 884. This symbol signifies which of the PXI (e) slots the card may be plugged into. Solution. For manual verification use the TB-4309 (ST) or TB-4309 (MT). PXIe-1085/PXIe-1078 PXI Platform Services Patch Details, May 2015. Provides support for NI GPIB controllers and NI embedded controllers. Remove all PXI (e) peripheral modules from the chassis. $250 Keysight 34970A DAQ. The "PWR OK/ FAUL" led is solid green. 1 NI-DAQmx 15. PNG 99 KB. Each PXI Trigger Line, PXI_Trig0 through PXI_Trig7, can be configured under the Routing. Switch 1 of SW1 controls the chassis inhibit mode. Now things seem to work. This warrant y includes parts and labor. JeffH2248. You can request repair, RMA, schedule calibration, or get technical support. オープンな業界規格であるPXIは、60社を超える計測器ベンダがおよそ1,500種類の. ini file to import in MAX . I have attached 2. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in up to. 3. I too cannot seem to add the target to a project. Power off the computer, then chassis. I'm using a PXIe-1078 chassis, using a PXIe-8360 MXI-Express card to interact with it. For example, the a white circle inside a white. Price may vary with addition of accessories and services. Hello everyone, I am using Veristand 2016 on a PXIe-1078 chassis with a PXIe-8135 controller with a PXIe-6363 MIO card and 5 PXI-e 4330 cards. This system was working fine a week ago, but now it will not work. Getting Started This chapter describes the key features of the PXIe-1084 chassis and lists the kit contents and optional equipment you can order from National Instruments. An the PXIe chassis containing the cards has disappeared. Hardware: Chassis: NI PXIe-1078 Multi-Function DAQs: 5 NI PXIe-6368 Timing Module: NI PXIe-6683H Goal: Use a reference trigger to acquire data from multiple tasks with each task containing channels from only one card (for multiple sampling rates). The 3,171 Square Feet single family home is a 3 beds, 2. 相关信息. 02-12-2014 10:06 AM. Re: Laptop and NI PXIe-1078. Controller PXIe-8135, Win10. Touch any metal part of the chassis to discharge static electricity. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. No cancelable / No retornable. PXIe, 9-Slot (5 Hybrid Slots, 3 PXI Express Slots), Up to 1. NI PXIe-1073 全部 >200 MB/s NI PXIe-1078 2, 3, 4 取决于控制器 NI PXIe-1078 5-9 >200 MB/s. ini to pxisys_old. System Configuration (API) Platform-Based Approach to Test and Measurement PXI Instrumentation . Email: PXIe-1075 National Instruments PXIe-1075 18-Slot, Up to 4 GB/s PXI Chassis from National Instruments | Buy Today from Artisan. Ambient temperature range. PXIe-1085 シャーシ内、または PXIe-1085 から MXI 経由で接続されたシャーシ内にある PXI-1 モジュールで、ごく稀に不正なデータを出力される事があります。. NI PXIe-10xx series 2 to 18 Slot PXI, PXIe Hybrid compatible Chassis. 5. 5 V to 60 V. Go to the product page. 08-04-2021 08:54 AM. 0 includes the PXIe-1085/PXIe-1078 patch that was released for PXI. PXI modules will show up correctly in any hybrid slot of the PXIe-1084 and PXIe-1088. PXI Platform Services 15. Each PXI Trigger Line, PXI_Trig0 through PXI_Trig7, can be configured under the Routing column to be one of four different options. 75 GB/s PXI Chassis—The PXIe‑1078 features a backplane that incorporates a PCI Express connection to every slot to meet a wide range of test and measurement application needs. Page 2 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 For further support information, refer to the NI Services appendix. Key Features. In its default position (OFF), the PXI Express controller controls the power supply on/off state based on the power switch on the chassis front panel. If you can get this config utility to run it allows the PXIe MXI board to power up the chassis when you power up the host (if you have a compatible MXI kit). 4. No driver for PXI-8512. 1까지의 버전이 설치된 PXIe-1085 및 PXIe-1078 섀시에 필요합니다. The PXIe-6509 provides programmable input filters for eliminating glitches or spikes and for debouncing digital switches or relays through a software-selectable digital filter. 2. If the PXI controller is connected to the internet, you can access it through remote desktop. Slot 2: Empty. If your chassis is not listed above, you can check the user manual for your chassis and see if it has replacement procedures. There is no signal from the controller to the monitor. The Triggers tab in MAX allows users to route triggers across buses. The NI PXIe-1078 nine-slot chassis features 1 GB/s total system bandwidth. Open a service request. 97 x 18. 2 GB/s into or out of the module. PXIe-1078 寸法図Method 1. Although synchronization can be done using the normal PXI trigger bus, the star trigger is a trigger signal that offers increased synchronization performance. 03-17-2021 08:54 AM. PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis. The maximum bandwidth for PXI chassis is 132MB/s. I decided the best thing to do is to rebuild the database. PRODUCT FLYER . 0 and later) I/O Modules; In general, all plug-in I/O modules supported with LabVIEW Real-Time or Windows XP are also supported under that OS on a hypervisor system (with the following exceptions)The PXIe-1066DC and PXIe-1086 do not allow local voltage monitoring; these two models have a Remote Fault (active high) pin that is asserted high when any chassis fault is detected. The PCIe‑8381 remote controller provides a x8 PCI Express link over a copper or fiber-optic cable to the. 1. Options/Accessories. Place the module edges into the module guides at the. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. For apertures less than 100 ms, add five times the typical rms noise to accuracy specification. Re: Powering up a PXI express chassis PXIe1078. The NI PCIe-8375 card is correctly installed into my PC and it, along with the PXIe-1078 Chassis are both present in MAX. NIの集録および信号調整デバイスをサポートします。. Program: the attached vi makes 2 tasks with the. I have the NI-XNET 18 and runtime, and NI-CAN installed and have tried the card in another. 561982-3D. 1. Important information To report an issue with this product, click here . National Instruments PXIe-1090 2-Slot PXI Express Chassis. You use it for processor-intensive, modular instrumentation, and data acquisition applications. 제품 관련 문서를 통해 제품의 사용법 및 활용법을 알아보십시오. PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. i. NI_PXIe-1078 Datasheet 1. When it is powered on I see that the power. Options. You can select PXI Advisor»Start Building Your System. お問い合わせ. If more bandwidth is needed, consider upgrading to PXIe. . アカウント. Click the Download button to access the site. PXI-8108. This same chassis with a PXIe-8360 controller card connected to an older laptop via ExpressCard-8360 works just fine with all PXIe and PXI cards installed. crossrulz. System Configuration (API) Platform-Based Approach to Test and. Getting Started w/ PXIe-1078, Trouble with PXI-4070 drivers, configuring MAX, using SoftDMM. Note Specifications are subject to change without notice. R2012a added a new functionality to set your devices reference clock to the PXI chassis backpane 10 MHz clock PXI_CLK10, so that all the modules in your chassis will share the same clock. I am setting up test bench and just added a PXI-5105 card to my PXIe-1078 chassis. PXIe-8398 또는 PXIe-8398과 같은 Gen3 x16 MXI 보드를 사용하는 경우 약간의 힘으로 케이블을 거꾸로 삽입 할 수 있습니다. Please note that the glyphs are also shown in the upper right hand corner of any PXI or PXIe card, adjacent to the fixing screw. You can configure your system so that the PXIe-8115 automatically powers on when AC power is restored to the PXIe-1078. The issue could be coming from the desktop. National Instruments PXIe-1090 2-Slot PXI Express Chassis. 2. The PXIe-1078 incorporates a system controller slot which is 4 slots wide. i. The 1,005 Square Feet single family home is a 3 beds, 1 bath property. PXIe-8133 Linux用NI Real-Time Hypervisorをプリインストールしたシステムは現在販売していません。 Linux OSと開発環境に対応したNI Real-Time Hypervisorを付属のマニュアルを参照して手動でインストールする必要があります。PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. We use the mid-market rate for our Converter. import chassis INI file into MAX. The chassis includes a 10 MHz reference clock with an accuracy of ±25 parts per million (ppm), less than 5 ps jitter, and a maximum slot-to-slot skew of 250 ps. Specifically, the trigger signal has a propagation delay of no more than. The power cord grounds the chassis and protects it from electrical damage while you install the module. The PXIe‑8840 includes two 10/100/1000BASE‑TX (Gigabit) Ethernet ports, two USB 3. For example, the a white circle inside a white. PXIe-1078 This document includes specifications for the PXIe-1078 chassis. Here, you can click the Chassis tab and select the PXI Express Chassis you are interested in purchasing. Get support on a product. NI Employee (retired) 02-08-2021 02:25 AM. I am using 1078 chassis with 6541 card, and 8381 controller (PCIe-8381 in my PC). 5" SSD, PXIe, Single Slot Storage, SSD. 新規サービスリクエストを開始. Options. PXIe, 10-Slot (7 Hybrid Slots, 1 PXI Express System Timing Slot, 1 Peripheral Expansion Slot), Up to 24 GB/s PXI Chassis. PXIe-1078 PXIe-1078 Rack Mount Issue Details I need to know the part number for the Mount Kit for the PXI-1078. 3 dBA High fan 74. 10-28-2021 03:24 AM. If the light does not come on or flashes red, then try the following: Make sure the chassis is plugged in to a working power source. PXIe_SYNC100 to every peripheral slot with an independent driver for. It's quite noisy (50dBA). 75 GB/s PXI Chassis—The PXIe‑1078 features a backplane that incorporates a PCI Express connection to every slot to meet a wide range of test and measurement application needs. 8. PXIe - PXI: PXIe and PXI use different bus architectures. All analog input channels in all cards are configured for single point input. One of the options is Rack Mount Kits. The PXIe‑5114 low-cost PXI oscilloscope has two channels that sample up to 250 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. com. The NI PXIe-1078 User Manual describes the features of the NI PXIe-1078 chassis and contains information about configuring the chassis, installing the modules, and operating. I do realize that is not Thunderbolt, just USB-C. This is going to be a 'real' system, all modules will be installed in a PXIe-1078 Chassis (9 slots). PXIe, 9-Slot (5 Hybrid Slots, 3 PXI Express Slots), Up to 1. NATIONAL INSTRUMENTS PXIE-1078 (01) PDF MANUAL; 3. Click "View Accessories" and go to section OPTIONAL ACCESSORIES>>Chassis Mounting Accessories. Note that if an additional chassis were required, the PXIe-8398 could be replaced with another PXIe-8399, allowing for further expansion. PXIe-1078 This document includes specifications for the PXIe-1078 chassis. 0 Kudos Message 1 of 6 (5,028 Views) Reply. PXIe-4331. chassis: NI PXIe-1078 . The PCIe-5663 VSA has no connection on the PXI lines, its only PXIe. The NI PXIe-1078 is warranted against def ects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. For manual verification use the TB-4309 (ST) or TB-4309 (MT). ini. 4. I have a PXIe-1078 chassis with a PXIe-8115 controller running Pharlap. Now, when you go to the Modules tab, you. US continental orders over $49 and under. 12 KB. 2 0 to 45 °C when used with the NI PXIe-1071, NI PXIe-1078 (with kit part number 158034A-01), or NI PXIe-1086 chassis. PXIe-1082 or PXIe-1078. In this document, you will find the instructions on how to update the firmware of your PXI/PXIe chassis. PXIe 1082 firmware update fails. The other cards consist of a PXIe-4137, 4 PXIe-2527, a PXI-4065, and a PXI-6602. e. My PXIe 1078 has no controller module in it, making it effectively just an extension to the pc it is connected to. 1. pxie-1078 pxie-1082 pxie-1082dc pxie-1085 pxie-1086 pxie-1095 问题详述 pxi机箱中每个插槽的正下方都显示一个符号。他们的意思是什么? 解决方案 与各种pxi插槽关联的字形列表如下所示。.